Project Examples

/Project Examples
Project Examples 2017-05-28T15:43:21+00:00
Search
We could not find any projects
We could not understand the location
  • - Make sure all street and city names are spelled correctly.
  • - Make sure your address includes a city and state.
  • - Try entering a zip code.
Search
Resize the map
157 Result(s)
Default
  • Project Date (Latest first)
  • Project Date (Oldest first)
  • Dosage (Highest lbs./cu.yd.)
  • Dosage (Lowest lbs./cu.yd.)
  • Title A to Z
  • Title Z to A
Refine Search
Application
Environment
Key Benefit
Fiber Product
Project Date
Fiber Length
Dosage
Loading

FORTA-FERRO® - Topping Slab
Fiber Length: " | Dosage: lbs./cu. yd.

FORTA-FERRO® was used to reinforce a polished concrete floor topping slab for Biji Living in Malaysia.

FORTA-FERRO® - Pavement
Fiber Length: 2.25" | Dosage: 3.0lbs./cu. yd.

The TCP (Thin Concrete Pavement ) system was successfully utilized for this heavy truck-traffic pavement project in Ft. Worth, TX using FORTA-FERRO®.

FORTA-FERRO® - Slab-On-Ground
Fiber Length: 2.25" | Dosage: 5.5lbs./cu. yd.

This distribution center warehouse in South Korea utilized FORTA-FERRO® to reinforce their slab-on-ground applications.

FORTA-FERRO® - Other, Pavement, Slab-On-Metal-Deck
Fiber Length: 2.25" | Dosage: 5.0lbs./cu. yd.

FORTA-FERRO® was used to reinforce a bridge deck in Minnesota.

FORTA-FERRO® - Shotcrete
Fiber Length: " | Dosage: lbs./cu. yd.

FORTA-FERRO® was used in a shotcrete application for a rockfall protection system in New Zealand.

FORTA-FERRO® - Parking Lot, Pavement, Slab-On-Ground
Fiber Length: " | Dosage: lbs./cu. yd.

FORTA-FERRO® was used to reinforce a topping slab for this crayon factory expansion project as well as the parking lot outside of the building.

FORTA-FERRO® - Slab-On-Ground
Fiber Length: " | Dosage: lbs./cu. yd.

FORTA-FERRO® was used to reinforce a basketball court slab-on-ground in Malaysia.

FORTA-FERRO® - Slab-On-Metal-Deck
Fiber Length: 2.25" | Dosage: 7.5lbs./cu. yd.

A multiple story building was in need of a superior reinforcement method and chose FORTA-FERRO® due to its ability to reduce cracking and project costs.

FORTA-FERRO® - Slab-On-Ground
Fiber Length: " | Dosage: 7.5lbs./cu. yd.

FORTA-FERRO® was used in an slab-on-ground for a warehouse in Aliquippa, PA due to its ability to save the project time and money.

FORTA-FERRO® - Slab-On-Ground
Fiber Length: 2.25" | Dosage: 7.5lbs./cu. yd.

FORTA-FERRO® was used in a large Phillips Electronics warehouse facility slab-on-ground project that needed to withstand heavy impacts with limited cracking.

FORTA-FERRO® - Slab-On-Ground
Fiber Length: " | Dosage: lbs./cu. yd.

FORTA-FERRO® was used to reinforce a bungalow slab-on-ground in Malaysia.

FORTA-FERRO® - Extended Joint, Slab-On-Ground
Fiber Length: 2.25" | Dosage: 5.0lbs./cu. yd.

To reduce volume of joints and while also reinforcing, Ober Industries in Saxonburg, PA, chose to use FORTA-FERRO®.

Econo-Mono® - Slab-On-Metal-Deck
Fiber Length: " | Dosage: lbs./cu. yd.

ECONO-MONO® was used to reinforce a balcony slab for an apartment in Malaysia.

FORTA-FERRO® - Slab-On-Ground
Fiber Length: 2.25" | Dosage: 3.5lbs./cu. yd.

FORTA-FERRO® was used in slab-on-ground applications for the 2016 Antalya Expo in Turkey.

FORTA-FERRO® - Slab-On-Ground
Fiber Length: 2.25" | Dosage: 7.0lbs./cu. yd.

FORTA-FERRO® was used in a slab-on-ground application to replace rebar for a office space construction project.